Yatık ve Dik Tip Otoklavlar
CL Serisi Dik Tip Otoklav
Dokümanlar
- ALP CL Series Autoclave Catalogue.pdf
- ALP CL-32L Model Otoklav Teknik Şartnamesi.doc
- ALP CL-32S Model Otoklav Teknik Şartnamesi.doc
- ALP CL-40L Model Otoklav Teknik Şartnamesi.doc
- ALP CL-40M Model Otoklav Teknik Şartnamesi.doc
- ALP CL-40MDP Model Otoklav Teknik Şartnamesi.doc
- ALP CL-40MDVP Model Otoklav Teknik Şartnamesi.doc
- ALP CL-40S Model Otoklav Teknik Şartnamesi.doc
Basic |
CL-32S |
CL-32L |
CL-40S |
CL-40M |
CL-40L |
|
With warm air drying |
CL-32SDP |
CL-32LDP |
CL-40SDP |
CL-40MDP |
CL-40LDP |
|
Chamber(usable inner size) Capacity |
Ø320x420mm 34L |
Ø320x676mm 54L |
Ø400x478mm 60L |
Ø400x672mm 85L |
Ø400x832mm 105L |
|
Usable max.temperature Usable max.pressure |
140°C 0.27MPa |
137°C 0.25MPa |
||||
Usable temperature |
Sterilization:101~ 140°C |
Sterilization: 101 ~ 137 °C |
||||
Dissolving : 40~100°C, Warming : 40~60 °C |
||||||
Usable time |
Sterilization, Dissolving :0min.~48hrs. 00min. and continuous, Warming : 0min.~48hrs.00min |
|||||
Controller |
Microprocessor controller, graphic display Temperature--·3digits, PID control Timer--·2digits hours : 2digits minutes, down count (Temperature/ Time integration system) |
|||||
Operation pattern |
A : Heating --+ Sterilization --+ Exhaust(adjustable) B : Heating --+ Sterilization--+ Exhau st(adjustable) --+ Warming C : Dissolving --+ Warming |
|||||
|
Operation pattern with drying |
D : Heating --+ Sterilization--+ Drain --+ Drying E : Only drying |
||||
|
Drying devices |
Hot air circulating and discharge by electric heater and air pump through 0.2 um micro cartridge filter of untake passage Temperature range : 60~150°C, Timer range :0min.~99hrs.59min. and continuous |
||||
Air exhaust device |
Temperature(99°C· ·adjustable) sensing · time(3min.--·adjustable) control & solenoid valve (Timed free steaming system) |
|||||
Exhaust cooling system |
Water storage tank with cooling coil & Exhaust drain receiver bottle |
|||||
Drain valve |
Manual valve at inner side of exhaust bottle : CL models Manual & automatic valve : CL-DP models |
|||||
|
Auto. water supply |
Automatic water supply system from city-water-faucet by level sensor ·controller |
||||
|
Pre-heat system |
To shorten the come-up time, at 60°C . Provided only with auto. water supply. |
||||
|
Rapid cooling system |
Chamber cooling system by 1~2 fans |
||||
|
Safety devices |
lnterlock system, Electro mechanical lock system Double check system of lid close, Over pressure detector Over temperature detector, Water lack preventor, Sensor break indicator Abnormal time indicator, Memory of power failure, Safety valve Breaker for slight leakage, over current & short circuit |
||||
|
Safety valve operation |
0.29M Pa |
0.27MPa |
|||
|
Water test pressure |
0.58MPa |
0.54MPa |
|||
Chamber & lid |
Stainless steel SUS304, shiny polished. Molded silicon rubber lid gasket (self-seal system) |
|||||
Outer panel |
Steel with baked melamine finish. Top panel : Heat-resisting molded resin |
|||||
Power demand (50/60Hz) |
AC220 / 230 / 240V, 1 phase, 50/60Hz |
|||||
2.6kW, 12A |
4.0kW, 18A |
4.4kW, 20A |
||||
Outer dimensions WXDXH |
550 x 550 x 870mm |
550 x 550 x 990mm |
620x650x880mm |
620x650x1000 mm |
620x650x1160mm |
|
Weight |
56kg |
60kg |
72kg |
78kg |
84kg |
|
|
Stainless wire basket |
Ø300x200mmx2pcs |
Ø300x300mmx2pcs |
Ø380x200mmx2pcs |
Ø380x300mmx2pcs |
Ø380x400mmx2pcs |
Standard for CL models as above. Optional for all CL-DP models. |
||||||
|
Others |
Exhaust bottle & chamber drain tray (for CL models). Stainless flexible drain hose (for CL-DP models) |
||||
Optional accessories |
Object temperature sensor, Printer, Recorder, Basket with pan, Bucket, Dressing drum |